Home / How DPM reading works

How DPM codes are actually read

Direct part marking does not create contrast. It creates geometry. That single fact explains most reading failures.

A dot peen mark has no colour

A printed label has dark ink on light paper. A dot peen mark is a series of indentations in the metal. There is no ink, and on many alloys there is almost no visible difference in brightness. A reader looking for black-white edges finds nothing to threshold.

What the reader actually detects

The indentation changes the local surface angle. When light arrives at a shallow angle, each dot catches light on one wall and shadows on the other. The reader sees the mark as a pattern of highlights and shadows, then reconstructs a binary image before decoding. This is why illumination angle matters more than resolution for DPM.

Three variables that decide whether it reads

Why "buy more megapixels" often does not help

Resolution decides whether individual dots are separable. Illumination decides whether they are visible at all. If the mark is invisible under the installed light, doubling the sensor gives you a sharper image of nothing.

What we do differently

Our fixed-mount readers offer independently controlled light groups, including polarised, so the lighting can be matched to the surface without changing the reader. The handheld VHS5000 carries switchable illumination for the same reason.

Test it on your own part

The only reliable answer is your mark, your alloy, your light. We sell a sample unit rather than promising a read rate: order one, run your own codes, and keep it as a spare if it does not fit.

Buy a sample Ask a question