Automotive parts plant, anonymised at the customer's request.
The station marked brackets with a laser and read them back before packing. Codes read fine on the bench. On the line, the same parts failed intermittently — the operator had to stop, wipe the part, and re-trigger, which broke the cycle time.
Replacing the reader with a higher-resolution unit made no difference. Increasing exposure read more codes but slowed the cycle. The actual cause was illumination: the laser mark on that alloy reflected a narrow band of light straight back, flattening the contrast the decoder depends on.
A fixed-mount reader with independently controlled light groups, including a polarised option, was installed on trial. The polarised group removed the specular return, and the mark separated from the surface without changing the cycle time.
The station no longer requires operator intervention during the shift, and the failure mode is understood: it was light, not resolution. The plant now specifies illumination type on new stations rather than only megapixels.
This is one station in one plant. We are not claiming a universal percentage improvement — the same part, alloy and mark combination had to be tested to get there. That is why we sell a sample unit rather than promise a number.